Adopted Documents We Assess Against

Development plan: Brent Local Plan 2019-2041 (adopted 14 February 2022)

DocumentTypeVersionMonitor Status
Residential Extensions & Alterations SPD Residential Extensions SPD Adopted 16 January 2025 Current checked 4 August 2026
Brent Local Plan 2019-2041 Local Plan Adopted 14 February 2022 Source link broken

Documents are re-checked against the council's own website weekly. A detected change flags "Policy Update Available" for human review — live assessment standards are never replaced automatically.

London Borough of Brent standards at a glance

9 numeric standards taken from London Borough of Brent's own adopted documents, each shown with the paragraph it comes from. Figures differ between councils — these are this one's.

Rear extension depth

up to 6m
Brent's 2025 guidance is generous - up to 6 metres deep for a terrace or semi - but never more than half your garden, and the garden you keep must still be big enough. Brent SPD paragraph 3.1.2
up to 8m
A detached house in Brent can extend up to 8 metres to the rear at single storey - if the garden is deep enough to give half of it up. Brent SPD paragraph 3.1.3
up to 4m
Brent allows a rear extension up to 4 metres tall with a pitched roof, but the eaves along the neighbour's fence must stay low - 2.5 to 3 metres. Brent SPD paragraphs 3.1.5-3.1.8

Two storey rear

up to 3m
A two-storey rear extension on a Brent terrace or semi is limited to 3 metres deep and must pass the 45-degree test from the neighbours' windows. Brent SPD paragraph 3.2.3
up to 4m
A detached house in Brent can take a two-storey rear extension up to 4 metres deep, subject to the 45-degree neighbour test. Brent SPD paragraph 3.2.4

Town centre

up to 1
Proposing more than one new takeaway in a Brent shopping frontage is very likely to be refused. A real scheme on Harrow Road was refused for exactly this, and only approved once the takeaways were taken out. Brent Local Plan Policy BE5 (provisional citation)

Amenity space

at least 50m²
A new ground-floor family home in Brent should normally have 50m² of private outdoor space, and 20m² for anything smaller. Meeting the area is not enough on its own - the space has to be reachable directly from the home, not round the side through a gate. Brent Local Plan Policy BH13 (provisional citation)

Highways access

at least 50%
At least half of a Brent front garden should stay planted or grassed. Squeezing in a second parking space is usually what pushes it under, and the two are judged together - so if the frontage is short on planting, the parking layout is normally what has to give. Brent Local Plan Policy BT2 (provisional citation)

Roof alterations

at least 0.2m
Brent only ask for 0.2 metres between the original eaves and the bottom of the dormer, which is generous. Side dormer windows also have to be obscure glazed to 1.7 metres above the floor. Residential Extensions SPD paragraphs 3.6.5 and 3.6.8

Standards are what the council normally expects, not a guarantee. A scheme outside them can still be approved on its merits, and one inside them can still be refused for another reason.

Authored Policy Library

16 local policy checks, each citation-locked to the adopted document. National policy (NPPF, national space and daylight standards) applies alongside these.

Residential Extensions & Alterations SPD

Brent Local Plan 2019-2041

← All covered authorities