Local Authority Profile
Elmbridge Borough Council
Adopted Documents We Assess Against
| Document | Type | Version | Monitor Status |
|---|---|---|---|
| Elmbridge Design Code | Design SPD | Adopted 17 April 2024 | Not yet checked |
Documents are re-checked against the council's own website weekly. A detected change flags "Policy Update Available" for human review — live assessment standards are never replaced automatically.
Elmbridge Borough Council standards at a glance
3 numeric standards taken from Elmbridge Borough Council's own adopted documents, each shown with the paragraph it comes from. Figures differ between councils — these are this one's.
Side extension form
Amenity neighbouring
Standards are what the council normally expects, not a guarantee. A scheme outside them can still be approved on its merits, and one inside them can still be refused for another reason.
Authored Policy Library
8 local policy checks, each citation-locked to the adopted document. National policy (NPPF, national space and daylight standards) applies alongside these.
Elmbridge Design Code
- Elmbridge Design Code section 6.6.2 — Side extension form (2 checks) Above ground-floor level, a side extension in Elmbridge should normally sit at least 1 metre back from the boundary - and more where the street pattern calls for it. At single-storey level, aim to keep the side wall at least 300mm off the boundary in Elmbridge, so foundations and guttering do not encroach on the neighbour's land.
- Elmbridge Design Code section 6.6.5 — Amenity neighbouring If your extension crosses a 45-degree line drawn from a neighbour's nearest window, Elmbridge will look more closely at daylight and sunlight impact - a single-storey extension projecting no more than 3 metres is treated as having minimal effect regardless.
- Design and Character SPD section 6.6.5 — Amenity neighbouring Under 3 metres deep Elmbridge treat the light impact as minimal. Beyond that, stay behind a 45-degree line from the edge of your neighbour's window.
- Elmbridge Design Code section 6.6.3 — Two storey rear A two-storey extension's roofline in Elmbridge should match the house it's attached to and line through at the same eaves height - it should never end up taller than the original roof.
- Elmbridge Design Code section 6.5.1 — Roof alterations A dormer in Elmbridge should line up with the windows below it and use roof materials that match the existing house - a hipped or gabled form is usually favoured over a flat-roofed box dormer.
- Elmbridge Design Code section 6.1.1 — Design materials Elmbridge asks applicants to state how much of the plot the building footprint covers (the plot ratio) and compare it with neighbouring plots - how much extension your plot can reasonably take depends on which of these area types it sits in.
- Elmbridge Design Code section 10 — Amenity neighbouring Elmbridge want 22 metres between the back windows of your home and the back windows facing you - more than most boroughs ask for.